Jiangsu Profile

Product List
32416. High-Performance Tinned Copper Wire for Extreme Heat Resistance
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...
32417. Durable Waterproof Electrical Wire for Industrial Heating Needs
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...
32418. High-Quality Insulated Electrical Heating Wire in Custom Colors
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...
32419. Premium Silicone Wire for High-Heat Applications - Flexible and Reliable
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...
32420. Extra Soft High-Temperature Silicone Wire for Electronics Projects
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...
32421. Premium Extra Soft High-Temperature Silicone Wire in Custom Colors
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ±0.1 0.3 335 0.6 0.8 2500 28awg 16/0.08TS 0.37 0.08 1.2 ...
32422. Premium Silicone Wiring Cable for High-Heat Project Needs
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ±0.1 0.3 335 0.6 0.8 2500 28awg 16/0.08TS 0.37 0.08 1.2 ...
32423. Premium Customizable 300V XLPE Electrical Wire in Vibrant Colors
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...
32424. Premium UL Certified High-Temperature Wire for Versatile Applications
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...
32425. Durable Copper Wire for Reliable Thermal Applications and Heating
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...
32426. Durable Tinned Copper Wire for Extreme Temperature Environments
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...
32427. Versatile Silicone Wire for Electronics with High-Temperature Resistance
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...
32428. High-Performance Silicone Wire for Electronics in Extreme Temperatures
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ±0.1 0.3 335 0.6 0.8 2500 28awg 16/0.08TS 0.37 0.08 1.2 ...
32429. High-Quality Heat-Resistant Silicone Rubber Wire for All Applications
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ±0.1 0.3 335 0.6 0.8 2500 28awg 16/0.08TS 0.37 0.08 1.2 ...
32430. Ultra Soft Heating Cable for Fast and Reliable Heating Solutions
[May 28, 2026]
[May 28, 2026] Conductor Sectional Area INSULATION Resistance Rated Current Max Current Length AWG No./mm O.D/mm mm2 O.D/mm THK/mm Ω /km A A m/Roll 30awg 11/0.08TS 0.31 0.055 0.8 ...












