2116. 35kv Indoor Support Type Epoxy Resin Casting Current Transformer
[May 07, 2026]
[May 07, 2026] Product Description Outline Drawing Technical Data Parameter Specification Rated insulation level 40.5/95/185kV Rated secondary current 5A or 1A The load power factor cos phi=0.8 (lag) Product standard GB20840.2-2014 ...
Company: Nantong Saler Electric Co., Ltd.
2117. Lzzbj9-35 Indoor Single-Phase Epoxy Resin Casting Current Transformer
[May 07, 2026]
[May 07, 2026] Product Description Outline Drawing Technical Data Parameter Specification Rated insulation level 40.5 / 95 / 185 kV Rated secondary current 5A or 1A The load power factor cos phi = 0.8 (lag) Product standard ...
Company: Nantong Saler Electric Co., Ltd.
2118. Indoor 10kv Single-Phase Epoxy Resin Casting Support Type Current Transformer
[May 07, 2026]
[May 07, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LQ(ZB)J-10 5-100 0.5 10 90 |1n/1s 225|1n 10P10 15 ...
Company: Nantong Saler Electric Co., Ltd.
2119. Ldzb8-10gy Indoor 10kv Epoxy Resin Cast Current Transformer
[May 07, 2026]
[May 07, 2026] Product Description Technical Specifications Rated Insulation Level: 12/42/75 kV Rated Secondary Current: 5A or 1A Rated Power Factor: cos phi = 0.8 (lagging) Instrument Security Factor: FS ≤ 10 Standard: GB/T ...
Company: Nantong Saler Electric Co., Ltd.
2120. 12kv Switchgear Molded by Epoxy Resin Bushing Insulating Plug
[May 06, 2026]
[May 06, 2026] Product Description Attribute Specification Rated Voltage 12kV Power Frequence 45kV/min Main Product Company Profile Nantong Saler Electric Co., Ltd. Traces its roots back to Shanghai Saler Electric Co., ...
Company: Nantong Saler Electric Co., Ltd.
2121. 35kv 1250A High Voltage C-Gis Epoxy Resin Insulating Sleeve
[May 25, 2026]
[May 25, 2026] Product Description Technical Parameters Rated Voltage Rated Current Power Frequency Partial Discharge Capacitance Value 35kV 1250A 95kV/min 45kV≤5pC 30±2pF Main Product Company Profile Nantong Saler Electric Co., Ltd. ...
Company: Nantong Saler Electric Co., Ltd.
2122. 35kv Gas-Insulated Bushings C-Type Casing Epoxy Resin Sf6 Bushing for Gis Switchgear
[May 25, 2026]
[May 25, 2026] Product Description Technical Parameters Rated Voltage Rated Current Power Frequency Partial Discharge Capacitance Value 35kV 630A 95kV/min 45kV≤5pC 18±2pF Main Product Company Profile Nantong Saler Electric Co., Ltd. ...
Company: Nantong Saler Electric Co., Ltd.
2123. High Voltage Insulator Type F Epoxy Resin Bushing for Gas Insulated Switchgear
[May 25, 2026]
[May 25, 2026] Product Description Technical Parameters Rated Voltage Rated Current Power Frequency Withstand Partial Discharge 35kV 2500A 95kV/min 45kV≤10pC Main Product Company Profile Nantong Saler Electric Co., Ltd. Traces its ...
Company: Nantong Saler Electric Co., Ltd.
2124. High Voltage C-Gis Epoxy Resin Insulating Sleeve for Gas Insulated Switchgear
[May 25, 2026]
[May 25, 2026] Product Description Technical Parameters Rated Voltage Rated Current Power Frequency Partial Discharge 35kV 1250A 95kV/min 45kV≤10pC Main Product Company Profile Nantong Saler Electric Co., Ltd. Traces its roots back to ...
Company: Nantong Saler Electric Co., Ltd.
2125. La (J) -10 Indoor Epoxy Resin Casting Penetrating Wall Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description The LQJ-10 (LAJ-10) series: precision current transformers for medium-voltage switchgear. Features a penetrating-wall structure, functioning as a sensor and support for busbars through cabinet ...
Company: Nantong Saler Electric Co., Ltd.
2126. Lzzbj9-150/4s 10kv Epoxy Resin Indoor Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 02S/0.510P10 10/10 ...
Company: Nantong Saler Electric Co., Ltd.
2127. Epoxy Resin Casting Insulation Current Transformer for 5A or 1A
[May 29, 2026]
[May 29, 2026] Product Description Rated Secondary Current: 5A or 1A Rated Insulation Level: 12/42/75kV Safety Factor (FS): ≤10 Pollution Class: Class II Load Power Factor: cos ø = 0.8 (lag) Product Standard: GB 20840.2-2014 compliant ...
Company: Nantong Saler Electric Co., Ltd.
2128. Saler-35/241 F-Type High Voltage C-Gis Epoxy Resin Insulating Bushing Sleeve
[May 27, 2026]
[May 27, 2026] Product Description Technical Parameters Rated Voltage Rated Current Power Frequency Withstand Partial Discharge 35kV 2500A 95kV/min 45kV≤10pC Main Product Company Profile Nantong Saler Electric Co., Ltd. Traces its ...
Company: Nantong Saler Electric Co., Ltd.
2129. Lzzbj9-150/2s Indoor Epoxy Resin Support-Type Current Transformer 10kv
[May 29, 2026]
[May 29, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LZZBJ9-150/2s 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 ...
Company: Nantong Saler Electric Co., Ltd.
2130. High Voltage 24kv Epoxy Resin Fuse Tube for C-Gis Systems
[May 29, 2026]
[May 29, 2026] Product Description Technical Parameters Rated Voltage Rated Current Power Frequency Partial Discharge Circuit Resistance 24kV 630A 65kV/min 28.8kV<5pC 125µΩ Main Product Company Profile Nantong Saler Electric Co., Ltd. ...