Made-in-china.com

Made-in-Jiangsu.com

Home » Featured Products »

paint

» Jiangsu Product List

Product List

Fast-Drying High Flashpoint Fire Retardant Coating for Steel Structures (Interior Use)
Contact Now

9706.

Fast-Drying High Flashpoint Fire Retardant Coating for Steel Structures (Interior Use) Open Details in New Window [Jul 21, 2026]

Product Description Parameter Result State in container Uniform, no lumps (after stirring) Surface drying time 3 hours Early crack resistance No cracks Adhesion strength 0.75 MPa Water resistance (24h) No peeling, ...

Company: Jiangsu Champion Technology Group Co., Ltd.

High Flashpoint Acrylic Modified Alkyd Intumescent Coating-Meets 2.5h Fire Rating
Contact Now

9707.

High Flashpoint Acrylic Modified Alkyd Intumescent Coating-Meets 2.5h Fire Rating Open Details in New Window [Jul 21, 2026]

Product Description Parameter Result State in container Uniform, no lumps (after stirring) Surface drying time 3 hours Early crack resistance No cracks Adhesion strength 0.75 MPa Water resistance (24h) No peeling, ...

Company: Jiangsu Champion Technology Group Co., Ltd.

Professional Grade Intumescent Fireproof Coating for Ordinary & Special Steel Structures
Contact Now

9708.

Professional Grade Intumescent Fireproof Coating for Ordinary & Special Steel Structures Open Details in New Window [Jul 21, 2026]

Product Description Parameter Result State in container Uniform, no lumps (after stirring) Surface drying time 3 hours Early crack resistance No cracks Adhesion strength 0.75 MPa Water resistance (24h) No peeling, ...

Company: Jiangsu Champion Technology Group Co., Ltd.

Solvent-Based Intumescent Fireproof Coating for Indoor Industrial & Civil Steel Buildings
Contact Now

9709.

Solvent-Based Intumescent Fireproof Coating for Indoor Industrial & Civil Steel Buildings Open Details in New Window [Jul 21, 2026]

Product Description Parameter Result State in container Uniform, no lumps (after stirring) Surface drying time 3 hours Early crack resistance No cracks Adhesion strength 0.75 MPa Water resistance (24h) No peeling, ...

Company: Jiangsu Champion Technology Group Co., Ltd.

High Flashpoint Steel Structure Fireproof Paint -Good Adhesion, Fast Curing, Safe Handling
Contact Now

9710.

High Flashpoint Steel Structure Fireproof Paint -Good Adhesion, Fast Curing, Safe Handling Open Details in New Window [Jul 21, 2026]

Product Description Parameter Result State in container Uniform, no lumps (after stirring) Surface drying time 3 hours Early crack resistance No cracks Adhesion strength 0.75 MPa Water resistance (24h) No peeling, ...

Company: Jiangsu Champion Technology Group Co., Ltd.

Champion Intumescent Coating for Indoor Steel -Fire Tested to 2.5 Hours
Contact Now

9711.

Champion Intumescent Coating for Indoor Steel -Fire Tested to 2.5 Hours Open Details in New Window [Jul 21, 2026]

Product Description Parameter Result State in container Uniform, no lumps (after stirring) Surface drying time 3 hours Early crack resistance No cracks Adhesion strength 0.75 MPa Water resistance (24h) No peeling, ...

Company: Jiangsu Champion Technology Group Co., Ltd.

High Flash High Solid Low Voc Alkyd Protective Coating for Steel
Contact Now

9712.

High Flash High Solid Low Voc Alkyd Protective Coating for Steel Open Details in New Window [Jul 22, 2026]

Product Description Parameter Value Solid content (by wt.) ≥70% Specific gravity 1.5 ± 0.2 kg/m³ Recommended DFT 50-80 μm Theoretical coverage 7-8 m²/kg (excluding loss) Touch dry (25°C) 0.5 hour Hard dry (25°C) 24 hour ...

Company: Jiangsu Champion Technology Group Co., Ltd.

Low Voc High Solid Alkyd Coating Custom Color Available
Contact Now

9713.

Low Voc High Solid Alkyd Coating Custom Color Available Open Details in New Window [Jul 22, 2026]

Product Description Parameter Value Solid content (by wt.) ≥70% Specific gravity 1.5 ± 0.2 kg/m³ Recommended DFT 50-80 μm Theoretical coverage 7-8 m²/kg (excluding loss) Touch dry (25°C) 0.5 hour Hard dry (25°C) 24 hour ...

Company: Jiangsu Champion Technology Group Co., Ltd.

High Solid Alkyd Anti-Rust Coating Long Service Life Eco Friendly
Contact Now

9714.

High Solid Alkyd Anti-Rust Coating Long Service Life Eco Friendly Open Details in New Window [Jul 22, 2026]

Product Description Parameter Value Solid content (by wt.) ≥70% Specific gravity 1.5 ± 0.2 kg/m³ Recommended DFT 50-80 μm Theoretical coverage 7-8 m²/kg (excluding loss) Touch dry (25°C) 0.5 hour Hard dry (25°C) 24 hour ...

Company: Jiangsu Champion Technology Group Co., Ltd.

Low Voc Alkyd Protective Coating for Metal Equipment and Tank
Contact Now

9715.

Low Voc Alkyd Protective Coating for Metal Equipment and Tank Open Details in New Window [Jul 22, 2026]

Product Description Parameter Value Solid content (by wt.) ≥70% Specific gravity 1.5 ± 0.2 kg/m³ Recommended DFT 50-80 μm Theoretical coverage 7-8 m²/kg (excluding loss) Touch dry (25°C) 0.5 hour Hard dry (25°C) 24 hour ...

Company: Jiangsu Champion Technology Group Co., Ltd.

High Flash Alkyd Coating for Steel Structure Anti-Rust Protection
Contact Now

9716.

High Flash Alkyd Coating for Steel Structure Anti-Rust Protection Open Details in New Window [Jul 22, 2026]

Product Description Parameter Value Solid content (by wt.) ≥70% Specific gravity 1.5 ± 0.2 kg/m³ Recommended DFT 50-80 μm Theoretical coverage 7-8 m²/kg (excluding loss) Touch dry (25°C) 0.5 hour Hard dry (25°C) 24 hour ...

Company: Jiangsu Champion Technology Group Co., Ltd.

High Flash Alkyd Coating Industrial Grade Factory Direct Supply
Contact Now

9717.

High Flash Alkyd Coating Industrial Grade Factory Direct Supply Open Details in New Window [Jul 22, 2026]

Product Description Parameter Value Solid content (by wt.) ≥70% Specific gravity 1.5 ± 0.2 kg/m³ Recommended DFT 50-80 μm Theoretical coverage 7-8 m²/kg (excluding loss) Touch dry (25°C) 0.5 hour Hard dry (25°C) 24 hour ...

Company: Jiangsu Champion Technology Group Co., Ltd.

Low Voc Alkyd Coating for Maintenance and Refurbishment
Contact Now

9718.

Low Voc Alkyd Coating for Maintenance and Refurbishment Open Details in New Window [Jul 22, 2026]

Product Description Parameter Value Solid content (by wt.) ≥70% Specific gravity 1.5 ± 0.2 kg/m³ Recommended DFT 50-80 μm Theoretical coverage 7-8 m²/kg (excluding loss) Touch dry (25°C) 0.5 hour Hard dry (25°C) 24 hour ...

Company: Jiangsu Champion Technology Group Co., Ltd.

Anti Rust High Flash Point High Solid High Gloss Alkyd Protective Coating
Contact Now

9719.

Anti Rust High Flash Point High Solid High Gloss Alkyd Protective Coating Open Details in New Window [Jul 22, 2026]

Construction Instructions 1. Use power tools or hand tools to stir thoroughly. Apply at 5 ° C to 40°C. 2. Application methods: airless spray, air spray, brush, roll. 3. Diluent: Exempted solvent, with an addition ratio ...

Company: Jiangsu Champion Technology Group Co., Ltd.

Quick Drying High Solid High Gloss High Flash Point Alkyd Industrial Coating
Contact Now

9720.

Quick Drying High Solid High Gloss High Flash Point Alkyd Industrial Coating Open Details in New Window [Jul 22, 2026]

Construction Instructions 1. Use power tools or hand tools to stir thoroughly. Apply at 5 ° C to 40°C. 2. Application methods: airless spray, air spray, brush, roll. 3. Diluent: Exempted solvent, with an addition ratio ...

Company: Jiangsu Champion Technology Group Co., Ltd.