57646. Weather Proof Double Acting Pneumatic Actuator
[Nov 27, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57647. Spring Return Pneumatic Actuator for Ball Valve
[Nov 27, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57648. Double Acting Pneumatic Actuator with Switches
[Nov 27, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57649. Spring Return Pneumatic Actuator with Switch
[Nov 27, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57650. Spring Return Pneumatic Actuator with Limit Switch Box
[Nov 25, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57651. Spring Return Pneumatic Actuator for Dn50 Ball Valve
[Nov 25, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57652. Compact Design Spring Return Pneumatic Actuator
[Nov 25, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57653. Spring Return Pneumatic Actuator for Dn32 Ball Valve
[Nov 25, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57654. Spring Return Flange Butterfly Valve Pneumatic Actuator
[Nov 25, 2020]

Spring Return Flange Butterfly Valve Pneumatic Actuator Our Service 1. Timely Delivery 2. Free sample can be provided. 3. Small order is accepted. 4. OEM is accepted. 5. DIN, JIS, ANSI, BS, JB, GB can be ...
Company: SEN Electromechanical Co., Ltd.
57655. Spring Return Pneumatic Actuator for Dn65 Ball Valve
[Nov 25, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57656. ISO5211 Direct Mount Spring Return Pneumatic Actuator
[Nov 25, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57657. Butterfly Valve Double Acting Pneumatic Actuator
[Nov 25, 2020]

Butterfly Valve Double Acting Pneumatic Actuator Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The ...
Company: SEN Electromechanical Co., Ltd.
57658. Light Weight Spring Return Pneumatic Actuator
[Nov 25, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57659. Cast Iron Housing Spring Return Pneumatic Actuator
[Nov 25, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...
Company: SEN Electromechanical Co., Ltd.
57660. Automatic Spring Return Pneumatic Actuator
[Nov 24, 2020]

Model selection of double acting: The suggested safety factor of double acting actuators is 20% - 30% under normal working conditions. Example: The torque needed by valve is 100 Nm. The torque ...