Jiangsu Profile

Product List
20446. Support Type Hermetically Casted 10kv Current Transformer Lzzbj9
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 02S/0.510P10 10/10 ...
Company: Nantong Saler Electric Co., Ltd.
20447. Lzzbj9-150/4s 10kv Epoxy Resin Indoor Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 02S/0.510P10 10/10 ...
Company: Nantong Saler Electric Co., Ltd.
20448. Lzzbj9-15/2s Type Post-Type Fully Enclosed Cast Resin Insulated Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LZZBJ9-150/2s 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 ...
Company: Nantong Saler Electric Co., Ltd.
20449. Lzzbj9-150/2s Indoor Epoxy Resin Support-Type Current Transformer 10kv
[May 29, 2026]
[May 29, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LZZBJ9-150/2s 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 ...
Company: Nantong Saler Electric Co., Ltd.
20450. 10kv Single-Phase Epoxy Casting Current Transformer for Power Distribution
[May 29, 2026]
[May 29, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LZZBJ9-10C5 5-400/5 0.2S/0.5/10P10 0.2S/10P10/10P10 ...
Company: Nantong Saler Electric Co., Ltd.
20451. 10kv Single-Phase Support-Type Current Transformer for Power Distribution Systems
[May 29, 2026]
[May 29, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LZZBJ9-10C5 5-400/5 0.2S/0.5/10P10 0.2S/10P10/10P10 ...
Company: Nantong Saler Electric Co., Ltd.
20452. 10kv Single-Phase Epoxy Casting Support-Type Current Transformer for Switchgear
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S(0.5)/10P10 0.2S/0.510P10 15/20 15/20 ...
Company: Nantong Saler Electric Co., Ltd.
20453. 10kv Single-Phase Support-Type Current Transformer for Power Distribution
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S(0.5)/10P10 0.2S/0.510P10 15/20 15/20 ...
Company: Nantong Saler Electric Co., Ltd.
20454. Lzzbj9-10A2g Indoor Epoxy Resin Support Type Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S(0.5)/10P10 0.2S/0.510P10 15/20 15/20 ...
Company: Nantong Saler Electric Co., Ltd.
20455. Epoxy Resin Casting Insulation Current Transformer for 5A or 1A
[May 29, 2026]
[May 29, 2026] Product Description Rated Secondary Current: 5A or 1A Rated Insulation Level: 12/42/75kV Safety Factor (FS): ≤10 Pollution Class: Class II Load Power Factor: cos ø = 0.8 (lag) Product Standard: GB 20840.2-2014 compliant ...
Company: Nantong Saler Electric Co., Ltd.
20456. 10kv Single-Phase Epoxy Casting Current Transformer for Indoor Power Systems
[May 29, 2026]
[May 29, 2026] Product Description Rated Secondary Current: 5A or 1A Rated Insulation Level: 12/42/75kV Safety Factor (FS): ≤10 Pollution Class: Class II Load Power Factor: cos ø = 0.8 (lag) Product Standard: Compliant with GB ...
Company: Nantong Saler Electric Co., Ltd.
20457. La (J) -10 Indoor Epoxy Resin Casting Penetrating Wall Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description The LQJ-10 (LAJ-10) series: precision current transformers for medium-voltage switchgear. Features a penetrating-wall structure, functioning as a sensor and support for busbars through cabinet ...
Company: Nantong Saler Electric Co., Ltd.
20458. Lmzk-10/6 Split Core Current Transformer for Rmu/Gis
[Apr 29, 2026]
[Apr 29, 2026] Product Description Specifications & Technical Data Model: LMZK-10/6 (High-Current / Large Aperture Type) Rated Secondary Current: 5A or 1A Accuracy Class: 0.2, 0.5, 1, 10P5, 10P10, 10P15 Aperture / Diameter: ID ...
Company: Nantong Saler Electric Co., Ltd.
20459. Jdzx9-35 Single-Phase Voltage Transformer 35kv Indoor Epoxy Resin Casting
[Apr 28, 2026]
[Apr 28, 2026] Product Description Overall Dimensions Dimension Mark Value Total Height 523 ± 3mm Total Length 385mm Total Width 235mm Mounting Hole Spacing (L) 315 ± 0.5mm Mounting Hole Spacing (W) 200 ± 0.5mm Base Hole Diameter ...
Company: Nantong Saler Electric Co., Ltd.
20460. Lmzk-10/5 Split Core Current Transformer, 10kv Large Aperture for Rmu/Gis
[Apr 28, 2026]
[Apr 28, 2026] Product Description Specifications & Technical Data Model: LMZK-10/5 (High-Current Type) Rated Secondary Current: 5A or 1A Accuracy Class: 0.2 / 0.5 / 1 / 10P5 / 10P10 Inner/Outer Diameter:$\Phi 75$ mm / $\Phi 136$ mm ...
Company: Nantong Saler Electric Co., Ltd.