Jiangsu Profile

Product List
16336. Ahkc-Ekcda Input Current AC 0~ (500-1500) a Output 4-20mA Split Core Hall Current Sensor for PLC ...
[Jun 02, 2022]
[Jun 02, 2022] Hall current sensors are mainly used to isolate and convert AC, DC, pulse, and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, ...
16337. Ahkc-H Input Current AC or DC 0~ (500-3000) a Output 5V/4V Split Core Hall Current Sensor for PLC ...
[Jun 02, 2022]
[Jun 02, 2022] Hall current sensors are mainly used to isolate and convert AC, DC, pulse, and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, ...
16338. Ahkc-Hb Input Current AC or DC 0~ (2000-8000) a 0~ (10000-20000) a Output 5V/4V Split Core Hall ...
[Jun 02, 2022]
[Jun 02, 2022] Hall current sensors are mainly used to isolate and convert AC, DC, pulse, and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, ...
16339. Ahkc-Ekca Input Current DC 0~ (500-1500) a Output 4-20mA Split Core Hall Current Sensor for PLC ...
[Jun 02, 2022]
[Jun 02, 2022] Hall current sensors are mainly used to isolate and convert AC, DC, pulse, and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, ...
16340. Ahkc-Hbaa Input Current DC 0~ (2000-8000) a 0~ (10000-20000) a Output 4-20mA Split Core Hall ...
[Jun 02, 2022]
[Jun 02, 2022] Hall current sensors are mainly used to isolate and convert AC, DC, pulse, and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, ...
16341. Ahkc-Ka Input Current AC or DC 0~ (500-5000) a Output 5V/4V Split Core Hall Current Sensor for PLC ...
[Jun 02, 2022]
[Jun 02, 2022] Hall current sensors are mainly used to isolate and convert AC, DC, pulse, and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, ...
16342. Actds-DV/V DC High Voltage Sensor for Solar PV DC Cabinet
[Jun 02, 2022]
[Jun 02, 2022] Take a photovoltaic DC cabinet as an example, take the photovoltaic DC cabinet need to monitor the output current and voltage of 8-channel photovoltaic combiner boxes as an example, since the general collector in the ...
16343. Ahkc-Hbda Input Current AC 0~ (2000-8000) a 0~ (10000-20000) a Output 4-20mA Split Core Hall ...
[Jun 02, 2022]
[Jun 02, 2022] Hall current sensors are mainly used to isolate and convert AC, DC, pulse, and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, ...
16344. Ahkc-F 200-800A Hall Effect Current Sensor for IDC Data Center Cabinet Incoming Line
[Jun 02, 2022]
[Jun 02, 2022] Hall current sensors are mainly used to isolate and convert AC, DC, pulse, and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, ...
16345. Xiyuan Mini Cost-Efficiency High Precision Unidirectional Piezoelectric Force Transducer ...
[Apr 28, 2026]
[Apr 28, 2026] Product Description Model number L1005 L1015 L1035 L1060 L1100 L1200 L1600 L1005A Range(KN) 5 15 35 60 100 200 600 5 Sensitivity (pC/N) 4 4 4 4 2 2 2 4 Self-resonant frequency(≥KHz) 75 70 60 50 40 30 15 70 Non-Linearity ...
16346. Xiyuan Customisable Analizador De Vibraciones Piezoelectric Accelerometer Vibration Sensor
[Apr 27, 2026]
[Apr 27, 2026] Product Parameters Dynamic Properties Range(peak) ±5,000g Sensitivity(25ºC) 1mV/g (160Hz) Frequency Response(±1dB) 1-12,000Hz Transverse Sensitivity Ratio ≤5% Electrical Properties Driving Voltage 18VDC-28VDC (current ...
16347. Non-Contact Split Type Eddy Current Sensor/Probe Measuring Displacement Sensor
[Apr 27, 2026]
[Apr 27, 2026] Product Parameters System Abbreviation Φ 5 system or 5mm system Φ 8 system or 8mm system Φ 11 system or 11mm system Φ 18 system or 18mm system Φ 25 system or 25mm system Model CWY-D0-401 CWY-D0-402 CWY-D0-404 ...
16348. High Precision Ceramic Capacitive Pressure Sensor with an Ntc Thermistor for Energy Storage Liquid ...
[Apr 23, 2026]
[Apr 23, 2026] Specification Operating Pressure: 0–10 barG (adjustable range available) Accuracy: ±1.0% FS @ 25°C Operating Temperature: -40°C to +135°C Media Temperature: -40°C to +135°C Storage Temperature: -40°C to +135°C Proof ...
16349. HONEYWELL CITY TECHNOLOGY NO 5NF 1,000PPM 5SERIES SENSOR AF508-W0C
[Apr 14, 2026]
[Apr 14, 2026] 1. General Information Item Details Product Name 5NF CiTiceL® Nitric Oxide (NO) Gas Sensor Part Number (without bias board) AF508-W0C Part Number (with bias board) AF509-W0C (5BNF) Document ...
Company: BNSENS Co., Ltd.
16350. HONEYWELL CITY TECHNOLOGY HCN 4HN 50PPM 4SERIES SENSOR AJ200-800
[Apr 14, 2026]
[Apr 14, 2026] 1. General Information Item Details Product Name 4HN CiTiceL® Hydrogen Cyanide (HCN) Gas Sensor Part Number AJ200-800 Document Purpose Present performance specification of the 4HN CiTiceL Related ...
Company: BNSENS Co., Ltd.



















