Jiangsu Profile

Product List
3016. La (J) -10 Indoor Epoxy Resin Casting Penetrating Wall Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description The LQJ-10 (LAJ-10) series: precision current transformers for medium-voltage switchgear. Features a penetrating-wall structure, functioning as a sensor and support for busbars through cabinet ...
Company: Nantong Saler Electric Co., Ltd.
3017. Support Type Hermetically Casted 10kv Current Transformer Lzzbj9
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 02S/0.510P10 10/10 ...
Company: Nantong Saler Electric Co., Ltd.
3018. Lzzbj9-150/4s 10kv Epoxy Resin Indoor Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 02S/0.510P10 10/10 ...
Company: Nantong Saler Electric Co., Ltd.
3019. Lzzbj9-15/2s Type Post-Type Fully Enclosed Cast Resin Insulated Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LZZBJ9-150/2s 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 ...
Company: Nantong Saler Electric Co., Ltd.
3020. Epoxy Resin Casting Insulation Current Transformer for 5A or 1A
[May 29, 2026]
[May 29, 2026] Product Description Rated Secondary Current: 5A or 1A Rated Insulation Level: 12/42/75kV Safety Factor (FS): ≤10 Pollution Class: Class II Load Power Factor: cos ø = 0.8 (lag) Product Standard: GB 20840.2-2014 compliant ...
Company: Nantong Saler Electric Co., Ltd.
3021. 10kv Single-Phase Epoxy Casting Current Transformer for Indoor Power Systems
[May 29, 2026]
[May 29, 2026] Product Description Rated Secondary Current: 5A or 1A Rated Insulation Level: 12/42/75kV Safety Factor (FS): ≤10 Pollution Class: Class II Load Power Factor: cos ø = 0.8 (lag) Product Standard: Compliant with GB ...
Company: Nantong Saler Electric Co., Ltd.
3022. Lzzbj9-150/2s Indoor Epoxy Resin Support-Type Current Transformer 10kv
[May 29, 2026]
[May 29, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LZZBJ9-150/2s 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 ...
Company: Nantong Saler Electric Co., Ltd.
3023. 10kv Single-Phase Epoxy Casting Current Transformer for Power Distribution
[May 29, 2026]
[May 29, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LZZBJ9-10C5 5-400/5 0.2S/0.5/10P10 0.2S/10P10/10P10 ...
Company: Nantong Saler Electric Co., Ltd.
3024. 10kv Single-Phase Support-Type Current Transformer for Power Distribution Systems
[May 29, 2026]
[May 29, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LZZBJ9-10C5 5-400/5 0.2S/0.5/10P10 0.2S/10P10/10P10 ...
Company: Nantong Saler Electric Co., Ltd.
3025. 10kv Single-Phase Epoxy Casting Support-Type Current Transformer for Switchgear
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S(0.5)/10P10 0.2S/0.510P10 15/20 15/20 ...
Company: Nantong Saler Electric Co., Ltd.
3026. 10kv Single-Phase Support-Type Current Transformer for Power Distribution
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S(0.5)/10P10 0.2S/0.510P10 15/20 15/20 ...
Company: Nantong Saler Electric Co., Ltd.
3027. Lzzbj9-10A2g Indoor Epoxy Resin Support Type Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S(0.5)/10P10 0.2S/0.510P10 15/20 15/20 ...
Company: Nantong Saler Electric Co., Ltd.
3028. Lsy3-10/110 Three-Phase Current Transformer Lsy3 Series for Power Metering and Protection
[May 29, 2026]
[May 29, 2026] Product Description Technical Data Parameter Specification / Value Rated Frequency 50/60Hz Rated Secondary Current 5A or 1A Rated Short Time Thermal Current 40kA, 2s Rated Continuous Thermal Current 1200% In Load Power ...
Company: Nantong Saler Electric Co., Ltd.
3029. Three-Phase Current Transformer Lsy3 Series for Power Metering and Protection
[May 29, 2026]
[May 29, 2026] Product Description Technical Data Parameter Specification / Value Rated Frequency 50/60Hz Rated Secondary Current 5A or 1A Rated Short Time Thermal Current 40kA, 2s Rated Continuous Thermal Current 1200% In Load Power ...
Company: Nantong Saler Electric Co., Ltd.
3030. Lsy3-10/110 Three-Phase Integrated Current Transformer for Indoor Switchgear
[May 29, 2026]
[May 29, 2026] Product Description Technical Data Parameter Specification / Value Rated Frequency 50/60Hz Rated Secondary Current 5A or 1A Rated Short Time Thermal Current 40kA, 2s Rated Continuous Thermal Current 1200% In Load Power ...
Company: Nantong Saler Electric Co., Ltd.