Jiangsu Profile

Famous Export Brand

Product List
6796. Lmzc 10/1 Dual Winding Current Transformer for Inflatable Cabinet
[Jun 02, 2026]
[Jun 02, 2026] Product Description Rated Secondary Current The Losd Power Factor Pollution class Altitude Rated frequency 5A or 1A cos Φ = 0.8 class ll ≤1000m 50/60Hz Main Product Company Profile Nantong Saler Electric Co., Ltd. Our ...
Company: Nantong Saler Electric Co., Ltd.
6797. Jszf1-6 (10) R Three Phase Epoxy Resin Casting Voltage Transformer
[Jun 02, 2026]
[Jun 02, 2026] Product Description Parameter Product Standard Rated Insulation Level Rated Frequency GB/T 20840.1,3 and IEC 61869-1,3 12/42/75 kV,7.2/32/60 kV 50 Hz or 60 Hz Main Product Company Profile Nantong Saler Electric Co., ...
Company: Nantong Saler Electric Co., Ltd.
6798. Lsy3-10/110 Three-Phase Current Transformer Lsy3 Series for Power Metering and Protection
[Jun 02, 2026]
[Jun 02, 2026] Product Description Technical Data Parameter Specification / Value Rated Frequency 50/60Hz Rated Secondary Current 5A or 1A Rated Short Time Thermal Current 40kA, 2s Rated Continuous Thermal Current 1200% In Load Power ...
Company: Nantong Saler Electric Co., Ltd.
6799. Medium Voltage Ring Core Current Transformer Lmzc-10/6 for Switchgear
[Jun 02, 2026]
[Jun 02, 2026] Product Description Rated Secondary Current The Losd Power Factor Pollution class Altitude Rated frequency 5A or 1A cos Φ =0.8 class ll ≤1000m 50/60Hz Main Product Company Profile Nantong Saler Electric Co., Ltd. Our ...
Company: Nantong Saler Electric Co., Ltd.
6800. La (J) -10 Indoor Epoxy Resin Casting Penetrating Wall Current Transformer
[Jun 02, 2026]
[Jun 02, 2026] Product Description The LQJ-10 (LAJ-10) series: precision current transformers for medium-voltage switchgear. Features a penetrating-wall structure, functioning as a sensor and support for busbars through cabinet ...
Company: Nantong Saler Electric Co., Ltd.
6801. Three-Phase Current Transformer Lsy3 Series for Power Metering and Protection
[Jun 02, 2026]
[Jun 02, 2026] Product Description Technical Data Parameter Specification / Value Rated Frequency 50/60Hz Rated Secondary Current 5A or 1A Rated Short Time Thermal Current 40kA, 2s Rated Continuous Thermal Current 1200% In Load Power ...
Company: Nantong Saler Electric Co., Ltd.
6802. 10kv Single-Phase Support-Type Current Transformer for Power Distribution Systems
[Jun 02, 2026]
[Jun 02, 2026] Product Description Type Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) LZZBJ9-10C5 5-400/5 0.2S/0.5/10P10 0.2S/10P10/10P10 ...
Company: Nantong Saler Electric Co., Ltd.
6803. Indoor Single-Phase Epoxy Resin Cast Voltage Transformer with Fuse Protection
[Jun 02, 2026]
[Jun 02, 2026] Product Description Main Product Company Profile Nantong Saler Electric Co., Ltd. Our Journey Founded in 2007 as Shanghai Saler Electric in Songjiang, Shanghai, we have dedicated over a decade to the electrical ...
Company: Nantong Saler Electric Co., Ltd.
6804. Jdz10-6/10b Indoor Single-Phase, Epoxy Resin Casting Type Voltage Transformer
[Jun 02, 2026]
[Jun 02, 2026] Product Description Main Product Company Profile Nantong Saler Electric Co., Ltd. Our Journey Founded in 2007 as Shanghai Saler Electric in Songjiang, Shanghai, we have dedicated over a decade to the electrical ...
Company: Nantong Saler Electric Co., Ltd.
6805. Lmzk-10/4 Split Core Current Transformer for Rmu/Gis
[Jun 02, 2026]
[Jun 02, 2026] Product Description Specifications & Technical Data Model: LMZK-10/4 (Dedicated for RMU/GIS) Rated Secondary Current: 5A or 1A Rated Frequency: 50/60Hz Inner/Outer Diameter: Φ65 mm / Φ136 mm Product Width: 70 mm ...
Company: Nantong Saler Electric Co., Ltd.
6806. Lmzk-10/3 Split Core Current Transformer for Inflatable Switchgear (RMU)
[Jun 02, 2026]
[Jun 02, 2026] Product Description Specifications & Technical Data Load Power Factor: cos=0.8 (lagging) Rated Secondary Current: 5A or 1A Rated Frequency: 50/60Hz Ambient Temperature: -5°C to +40°C (Daily average ≤ 30°C) Pollution ...
Company: Nantong Saler Electric Co., Ltd.
6807. Support Type Hermetically Casted 10kv Current Transformer Lzzbj9
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S/10P10 0.5/10P10 02S/0.510P10 10/10 ...
Company: Nantong Saler Electric Co., Ltd.
6808. 10kv Single-Phase Epoxy Casting Support-Type Current Transformer for Switchgear
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S(0.5)/10P10 0.2S/0.510P10 15/20 15/20 ...
Company: Nantong Saler Electric Co., Ltd.
6809. 10kv Single-Phase Support-Type Current Transformer for Power Distribution
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S(0.5)/10P10 0.2S/0.510P10 15/20 15/20 ...
Company: Nantong Saler Electric Co., Ltd.
6810. Lzzbj9-10A2g Indoor Epoxy Resin Support Type Current Transformer
[May 29, 2026]
[May 29, 2026] Product Description Rated current ratio(A) Accuracy classes combination Rated secondary output(VA) Short-time thermal current(kA/S) Raten dynamic current(kA) 5-400/5 0.2S/0.5 0.2S(0.5)/10P10 0.2S/0.510P10 15/20 15/20 ...
Company: Nantong Saler Electric Co., Ltd.